Specifications
| Connection Inlet Flange | DN 100 |
| Connection Outlet Flange | DN 100 |
| Cooling Method | Air Cooling |
| Power Supply Voltage | 3Ph 380-480V 50/60Hz |
| Power Total Rated | 44000.00 |
| Pressure Ultimate | 15000.00 |
CLAWVAC CPi 1600 B - Dry Claw Pump, 3Ph 380-480V 50/60Hz
Part Number: 10781600V01
Dry Claw Pumps
Vacuum dry claw pumps are positive displacement pumps that use two claw-shaped rotors to trap and compress a gas, creating a vacuum. These pumps are oil-free, ensuring clean and maintenance-free operation.
CLAWVAC CPi B System
The one-stop-shop solution for high central vacuum demands.
The unique product features of the CLAWVAC product line offer numerous advantages for the rough vacuum industry. The CLAWVAC CPi B System extends the line with a smart all-in-one multi-claw pump solution, combining all the benefits of the CLAWVAC with an intelligent controller and software to meet high process demands and provide energy efficiency, redundancy and easy maintenance.
Features and Benefits
- Pure performance
- Plug & Go
- Easy maintenance
- Smart controls & connectivity
- Maximized energy efficiency
- High capability for demanding applications
General Product Information
| Connection Outlet Flange | DN 100 |
| Connection Inlet Flange | DN 100 |
| Cooling Method | Air Cooling |
| Dimension Height | 1.98 |
| Dimension Length | 1.57 |
| Dimension Width | 1.46 |
| IP Rating | IP54 |
| Power Supply Frequency |
50 Hz
60 Hz |
| Power Supply Phase | 3-Ph |
| Power Supply Voltage | 3Ph 380-480V 50/60Hz |
| Weight | 1800.00 |
| Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
| Connection Inlet / Outlet Flange | DN 100 | DN 100 |
| Certification of Product |
CE
RoHS |
Environmental Conditions
| Temperature Ambient Operation Max | 40.00 |
| Temperature Ambient Operation Min | 0.000 |
Classification
| Classification Dry or Wet Pump | Dry |
| Classification Product Pressure Range | Rough Vacuum: 1000 mbar - 1 mbar |
| Classification High / Medium / Rough Vacuum pump | Rough Vacuum Pump |
| Classification Vacuum Pump Technology | Dry Claw Pump |
Performance Data
| Power Total Rated | 44000.00 |
| Pressure Ultimate | 15000.00 |
| Pumping Speed Air Nitrogen 50Hz | 0.422 |
| Pumping Speed Air Nitrogen 60Hz | 0.422 |