CERAVAC CTR 100 - DN 16 ISO-KF 10Torr

Part Number: 230302V01

Variant

Explore the range of variants given below to compare the product

Short Description Part Number Pressure Measurement Range
230300V01 1333 mbar / 0.133 mbar
230301V01 133 mbar / 0.01 mbar
230302V01 13.3 mbar / 0.001 mbar
230304V01 0.13 mbar / 1E-05 mbar
230305V01 1333 mbar / 0.133 mbar
230308V01 1.33 mbar / 0.0001 mbar

CERAVAC CTR

The CERAVAC CTR transmitters offer excellent accuracy and reproducibility. The CTR 100 and CTR 101 allow gas type independent pressure measurements and are able to tolerate bursts of pressure without suffering physical damage or calibration shifts. The robust sensor is suited for the most corrosive processes as the sensor is highly resistant to corrosion from common process chemicals. The sensor of the CTR 101 is internally heated and regulated to 45 °C to offer full-scale pressure ranges from 1000 to 0.1 Torr.

 

The CERAVAC CTR line is drop in replaceable for the CERAVAC CTR-N line with negligible impact.

Features and Benefits

  • Leading levels of accuracy (0.2%) achieved via the ceramic capacitive sensor
  • Excellent temperature compensation regardless of ambient conditions
  • Fast and accurate response times to pressure changes
  • Long-term stability: no calibration shifts after bursts of pressure
  • Measurement/display range: from 1000 Torr to 10-5, depending on the model

General Product Information

Cable Connector Comms Interface DSUB 15-PIN - Male
Connection Inlet Flange DN 16 ISO-KF (NW16)
Dimension Height 0.055
Dimension Length 0.095
Dimension Width 0.055
Power Supply Frequency DC Voltage
Power Supply Voltage DC 14-30V
Weight 0.370
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Pressure Measurement Range 13.3 mbar / 0.001 mbar

Classification

Classification Principle of Measurement Capacitance diaphragm vacuum gauges

Performance Data

Measurement Uncertainty 0.2 - 0.5% of reading
Power Consumption Max 1.00
Pressure Measurement Min 0.100
Pressure Measurement Max 1330.00

Environmental Conditions

Temperature Ambient Operation Max 50.00
Temperature Ambient Operation Min 5.00

Material of Construction

Material Exposed to Vacuum Aluminium oxide (Al2O3) Stainless Steel AISI 316L

Connectivity - Communication Interface

Communication Interfaces Customer 0-10 V (analog input - linear gauge)
Product Title Part Number Price Add to cart
Connection cable Type C - 5m 12455 EUR 173.00
Connection cable Type C - 10m 230022 EUR 207.00
Connection cable Type C - 15m 12456 EUR 235.00
Connection cable Type C - 20m 12457 EUR 256.00
Connection cable Type C - 30m 12458 EUR 373.00
Connection cable Type C - 50m 230345V01 EUR 399.00
GRAPHIX ONE 230680V01 EUR 1,469.00
GRAPHIX TWO 230681V01 EUR 2,215.00
GRAPHIX THREE 230682V01 EUR 2,675.00